Master High Fire/Individual High Fire/Editable Zones

Clicking on this button will toggle between Master High Fire, Individual High Fire, and Editable Zones. The Master High Fire setting will allow the controller to see the one digital input signal as a high fire signal for all burners.  Individual high fire will put the burners in groups of 4, each group being a separate zone.  Editable Zones will allow the user to determine the burner and zone configuration.  The high fire digital input is required for the e-TRIM system to provide band alarm and critical alarm information.  The default setting is master high fire.  The master high fire contact is terminal 1270 to terminal 1340, as shown in the electrical drawing in “Appendix C – Electrical Drawings (For Reference ONLY)”. See the electrical prints for more termination details.