Electrical Connections

 

The eFlo meter requires a 10-pin connector and cable for power and communications.  The eFlo is supplied with a 20 ft cable.  The wires are color-coded per the table below.  Contact SSi for a longer cable is required.

 

Wire-In Color

Signal Type

Description

Red

+ VDC

Power Supply (24 VDC @ 750mA)

Black

- VDC

Green / Black Stripe

+ RS485

Communications Signal Provided by Modbus Over Serial

Red / Black Stripe

- RS485

White / Black Stripe

RLY

Normally Open Relay Contact (24 VDC)

Orange / Black Stripe

RLY

Orange

+ mA

Analog Out - Output Flow Signal (4 - 20 mA)

Blue

- mA

Green

+ mA

Analog In - Input Setpoint Signal (4 - 20 mA)

White

- mA

Table 3 - Electrical Connections