Revision History

Rev.

Description

Date

MCO #

-

Initial Release

06-08-06

N/A

A

Updated SDS Download option (delete datalog files); Added SDS – Manage Survey Records menu option; Updated Menu Option 34 – Clear Logged Data (delete datalog files); Updated the SDS About screen; Updated the Control TCs screen; Updated Cold Junction menu screen (menu option 23); Added new data tags

01-12-07

N/A

B

Updated to reflect firmware revision 1.10 – New Cold Junction screen

01-31-07

N/A

C

Updated New Cold Junction screen; Added “Analog Inputs” information; Updated SDS Reporter menu options; Added “Appendix A – Standard Calibration Range” section; Updated “Revision History” section – added “MCO #” column; Updated Logo on title page; Added “Accuracy at 1600 Degrees F. with thermister error” column on page 6; Added note about “Accuracy at 1600 Degrees F. with thermister error” column; Modified descriptions for #md# and #xd# TC Offset tags

05-30-08

2060

D

Updated the template manager section to include changes for versions 1.101.0.76 & 1.101.0.80; Updated realtime screen; Added SDS:FC and SDS:IT data tags

08-14-08

2067

E

Added section for multiple survey reports;  Added data tags for multiple survey reports; Changed revision # in footer; Added sections for Print All, Export All; Updated View Real-Time screen

08-17-09

2074

F

Updated Screen 27 to be consistent with Firmware Version 1.18

2/10/2012

2096

G

Updated Screen 28 to be consistent with Firmware Version 1.24

3/7/2012

2098

H

Added Dip Switch Instructions

2/21/2017

2208

I

Added storage note

10/28/2021

2314