Appendix A: SDS Data Tags
|
Tag |
Description |
Usage |
|---|---|---|
|
SDS:OS |
Survey overall start |
<SDS:OS> |
|
SDS:OE |
Survey overall end |
<SDS:OE> |
|
SDS:AE |
Survey approach dates |
<SDS:AE> |
|
SDS:AT |
Survey approach times |
<SDS:AT> |
|
SDS:STST |
Survey stable start times |
<SDS:STST> |
| SDS:SU | Stabilization Time | <SDS:SU> |
|
SDS:FILE |
The filename the report is saved as |
<SDS:FILE> |
|
SDS:PD |
The current date when the report is printed |
<SDS:PD> |
|
SDS:PT |
The current time when the report is printed |
<SDS:PT> |
|
SDS:FID |
The furnace ID |
<SDS:FID> |
|
SDS:FM |
Furnace make/model |
<SDS:FM> |
|
SDS:FT |
Furnace type |
<SDS:FT> |
|
SDS:FU |
Furnace use |
<SDS:FU> |
|
SDS:FD |
Furnace dimensions |
<SDS:FD> |
|
SDS:FC |
Furnace Class |
<SDS:FC> |
|
SDS:FOR |
Furnace operating range |
<SDS:FOR> |
|
SDS:SD |
Survey date |
<SDS:SD> |
|
SDS:ST |
Survey time |
<SDS:ST> |
|
SDS:SDR |
Survey date range |
<SDS:SDR> |
|
SDS:DUR |
Duration of the survey |
<SDS:DUR> |
|
SDS:OP |
Operator. Survey performed by |
<SDS:OP> |
|
SDS:APP |
Survey approved by |
<SDS:APP> |
|
SDS:TITLE |
The heading, or title, of the report |
<SDS:TITLE> |
|
SDS:NOTE |
Notes for the survey |
<SDS:NOTE> |
|
SDS:TOL |
Survey tolerance / uniformity required |
<SDS:TOL> |
|
SDS:OTS |
Overtemp setpoint |
<SDS:OTS> |
|
SDS:SP |
Survey setpoint |
<SDS:SP> |
|
SDS:TCN |
Number of thermocouples |
<SDS:TCN> |
|
SDS:TCT |
Thermocouple type |
<SDS:TCT> |
|
SDS:TCS |
Thermocouple spool number |
<SDS:TCS> |
|
SDS:TCC |
Thermocouple calibrated by |
<SDS:TCC> |
|
SDS:TCCD |
Thermocouple calibration date |
<SDS:TCCD> |
|
SDS:TCCF |
Thermocouple spool correction factor |
<SDS:TCCF> |
|
SDS:SDN |
Next survey due date |
<SDS:SDN> |
|
SDS:SDSM |
Survey box make/model |
<SDS:SDSM> |
|
SDS:SDSS |
Survey box serial number |
<SDS:SDSS> |
|
SDS:SDSC |
Survey box calibrated by |
<SDS:SDSC> |
|
SDS:SDSCD |
Survey box calibration date |
<SDS:SDSCD> |
| SDS:SDSDD | Instrument Certification Due Date | <SDS:SDSDD> |
|
SDS:SDSCF |
Survey box correction factor |
<SDS:SDSCF> |
|
SDS:SPEC |
Specifications the survey meets |
<SDS:SPEC> |
|
SDS:INT |
Sample interval |
<SDS:INT> |
|
SDS:T |
Temperature character – F or C |
<SDS:T> |
|
SDS:SIM |
Simulate load, in pounds |
<SDS:SIM> |
|
SDS:OVS |
Overshoot (Deprecated) |
<SDS:OVS> |
|
SDS:MIC |
Microns |
<SDS:MIC> |
|
SDS:RES |
Survey result |
<SDS:RES> |
|
SDS:GRAPH600x400 |
Inserts a 600X400 image of the graph |
<SDS:GRAPH600x400> |
|
SDS:GRAPH600x400Overview |
Inserts a 600X400 overview chart image |
< SDS:GRAPH600x400Overview> |
|
SDS:COM |
Company name |
<SDS:COM> |
|
SDS:UDUR |
User defined survey duration |
<SDS:UDUR> |
|
SDS:UTCN |
User defined number of thermocouples |
<SDS:UTCN> |
|
SDS:PCT |
PID cycle time |
<SDS:PCT> |
|
SDS:PDB |
PID dead band |
<SDS:PDB> |
|
SDS:POL |
PID output limit |
<SDS:POL> |
|
SDS:PPB |
PID PB (gain) |
<SDS:PPB> |
|
SDS:PR |
PID rate |
<SDS:PR> |
|
SDS:PRE |
PID reset |
<SDS:PRE> |
|
SDS:CMF |
Temperature controller manufacturer |
<SDS:CMF> |
|
SDS:CMA |
Temperature controller make/model |
<SDS:CMA> |
|
SDS:IT |
Controller instrument type |
<SDS:IT> |
|
SDS:TCG |
Thermocouple gauge |
<SDS:TCG> |
|
SDS:OV |
Overshoot - yes or no |
<SDS:OV> |
|
SDS:OD |
Outputs TC and temp if overshoot occurred |
<SDS:OD> |
|
SDS:OVT |
Time the overshoot occurred |
<SDS:OVT> |
|
SDS:CTD |
Inserts a note regarding the control thermocouple. Inserts nothing if no control thermocouple was chosen |
<SDS:CTD> |
|
SDS:CTN |
Control thermocouple. Inserts “None” if none is defined |
<SDS:CTN> |
|
°# |
°degree type |
°# |
|
SDS:ED |
Survey end date |
<SDS:ED> |
|
SDS:ET |
Survey end time |
<SDS:ET> |
|
SDS:TCM |
Thermocouple map (image) |
<SDS:TCM> |
|
SDS:ApproachTables |
Inserts tables with approach data |
<SDS:ApproachTables> |
|
SDS:SurveyTables |
Inserts tables with survey data |
<SDS:SurveyTables> |
|
SDS:UD1 |
User defined field 1 |
<SDS:UD1> |
|
SDS:UD2 |
User defined field 2 |
<SDS:UD2> |
|
SDS:UD3 |
User defined field 3 |
<SDS:UD3> |
|
SDS:UD4 |
User defined field 4 |
<SDS:UD4> |
|
SDS:UD5 |
User defined field 5 |
<SDS:UD5> |
|
SDS:UD6 |
User defined field 6 |
<SDS:UD6> |
|
SDS:UD7 |
User defined field 7 |
<SDS:UD7> |
|
SDS:UD8 |
User defined field 8 |
<SDS:UD8> |
|
SDS:UD9 |
User defined field 9 |
<SDS:UD9> |
|
SDS:UD10 |
User defined field 10 |
<SDS:UD10> |
|
SDS:UD11 |
User defined field 11 |
<SDS:UD11> |
|
SDS:UD12 |
User defined field 12 |
<SDS:UD12> |
|
SDS:UD13 |
User defined field 13 |
<SDS:UD13> |
|
SDS:UD14 |
User defined field 14 |
<SDS:UD14> |
|
SDS:UD15 |
User defined field 15 |
<SDS:UD15> |
|
SDS:UD16 |
User defined field 16 |
<SDS:UD16> |
|
SDS:UD17 |
User defined field 17 |
<SDS:UD17> |
|
SDS:UD18 |
User defined field 18 |
<SDS:UD18> |
|
SDS:UD19 |
User defined field 19 |
<SDS:UD19> |
|
SDS:UD20 |
User defined field 20 |
<SDS:UD20> |
*** Survey scope data tags – {n} where n is the survey number – are used to display survey information for the multiple survey report feature. See the section Print Multiple Surveys for more information on how to use these data tags ***
Sample Output
|
Tag |
Sample Output |
|---|---|
|
SDS:FILE |
SDSReport1.sdsreport |
|
SDS:PD |
2/16/06 |
|
SDS:PT |
11:30:00 AM |
|
SDS:FID |
Batch 1 |
|
SDS:FM |
Furnace Mfg. |
|
SDS:FT |
Batch Gas Draw |
|
SDS:FU |
Temper |
|
SDS:FD |
24 x 15 x 12 |
|
SDS:FC |
A |
|
SDS:FOR |
650 - 1000°C |
|
SDS:SD |
2/16/06 |
|
SDS:ST |
11:30:00 AM |
| SDS:SU | 10 min |
|
SDS:SDR |
2/13 THRU 2/14 |
|
SDS:DUR |
00:30:00 |
|
SDS:OP |
Shaun Scott |
|
SDS:APP |
Scott Brown |
|
SDS:TITLE |
Test Survey 1 |
|
SDS:NOTE |
This is a test survey |
|
SDS:TOL |
[+/-] 10 |
|
SDS:OTS |
+10 |
|
SDS:SP |
750 |
|
SDS:TCN |
20 |
|
SDS:TCT |
K |
|
SDS:TCS |
Z458 |
|
SDS:TCC |
Soandso |
|
SDS:TCCD |
1/15/06 |
|
SDS:TCCF |
-1 |
|
SDS:SDN |
2/28/06 |
|
SDS:SDSM |
SSI SDS8120 |
|
SDS:SDSS |
SDS60293201 |
|
SDS:SDSC |
Super Systems Inc |
|
SDS:SDSCD |
1/15/12 |
| SDS:SDSDD | 2/6/2020 |
|
SDS:SDSCF |
-1.0 |
|
SDS:SPEC |
AMS 2750-D and E |
|
SDS:INT |
10s |
|
SDS:T |
F |
|
SDS:SIM |
500 |
|
SDS:OVS |
None |
|
SDS:MIC |
N/A |
|
SDS:RES |
Passed |
|
SDS:GRAPH600x400 |
[An image of the graph] |
|
SDS:COM |
Company Name |
|
SDS:UDUR |
30 mins |
|
SDS:UTCN |
20 |
|
SDS:PCT |
20 |
|
SDS:PDB |
2 |
|
SDS:POL |
2 |
|
SDS:PPB |
2 |
|
SDS:PR |
2 |
|
SDS:PRE |
2 |
|
SDS:CMF |
Super Systems |
|
SDS:CMA |
7EK |
|
SDS:IT |
B |
|
SDS:TCG |
16 |
|
SDS:OV |
Yes |
|
SDS:OD |
TC6 - 1700° |
|
SDS:OVT |
5:30 |
|
SDS:CTD |
TC5 is the control TC, and is not used in uniformity survey results |
|
SDS:CTN |
TC5 |
|
°# |
°F |
|
SDS:ED |
2/16/06 |
|
SDS:ET |
11:30:00 AM |
|
SDS:TCM |
[Thermocouple image] |
TC Offsets
|
Tag |
Description |
Usage |
|
#o1# |
Offset for TC1 |
#o1# |
|
#cf1# |
Individual correction factor for TC1 |
#cf1# |
|
#o1# |
-1 |
|
Min/Max/Mean/Spread/Deviation
|
Tag |
Description |
Usage |
|
#n1# |
Minimum temp for TC1 within the selected survey region. Substitute numbers for other TCs |
#n1# |
|
#x1# |
Max temp for TC1 |
#x1# |
|
#m1# |
Mean temp for TC1 |
#m1# |
|
#s1# |
Spread for TC1 |
#s1# |
|
#vn1# |
Deviation @min temp from setpoint for TC1 |
#vn1# |
|
#vx1# |
Deviation @max temp from setpoint for TC1 |
#vx1# |
|
#vm1# |
Deviation @mean temp from setpoint for TC1 |
#vm1# |
|
#mtcn# |
Minimum TC number |
#mtcn# |
|
#mtan# |
Minimum TC number during approach segment |
#mtan# |
|
#mtav# |
Minimum TC value during approach segment |
#mtav# |
|
#mtcv# |
Minimum TC value |
#mtcv# |
|
#mtcx# |
The maximum temperature of the minimum TC |
#mtcx# |
|
#md# |
Minimum calculated survey TC absolute deviation from setpoint |
#md# |
|
#rect# |
Recovery Time – the time between the when the first TC comes into tolerance the time when the last TC comes into tolerance |
#rect# |
|
#xtcn# |
Maximum TC number |
#xtcn# |
|
#xtan# |
Maximum TC number during approach segment |
#xtan# |
|
#xtav# |
Maximum TC value during approach segment |
#xtav# |
|
#xtcm# |
Minimum temperature of the maximum TC |
#xtcm# |
|
#xtcv# |
Maximum TC value |
#xtcv# |
|
#xd# |
Maximum calculated survey TC absolute deviation from setpoint |
#xd# |
|
#sxd# |
Maximum TC value – setpoint |
#sxd# |
|
#smd# |
Minimum TC value – setpoint |
#smd# |
| #itct# | Initial Threshold Cross Time | #itct# |
| #itctc# | Initial Threshold Cross TC Number | #itctc# |
| #ftct# | Final Threshold Cross Time | #ftct# |
| #ftctc# | Final Threshold Cross TC Number | #ftctc# |
| #mtct# | Minimum TC Time | #mtct# |
| #xtct# | Maximum TC Time | #xtct# |
| #mtav# | Minimum TC Approach Value | #mtav# |
| #mtan# | Minimum TC Approach Number | #mtan# |
| #xtav# | Maximum TC Approach Value | #xtav# |
| #xtan# | Maximum TC Approach Number | #xtan# |
|
Tag |
Sample Output |
|
#n1# |
183 |
|
#x1# |
183 |
|
#m1# |
183 |
|
#s1# |
12.5 |
|
#vn1# |
383 |
|
#vx1# |
383 |
|
#vm1# |
383 |
|
#mtcn# |
2 |
|
#mtan# |
2 |
|
#mtav# |
150 |
|
#mtcv# |
1 |
|
#mtcx# |
500 |
|
#md# |
201.0 |
|
#rect# |
3 mins 30 secs |
|
#xtcn# |
1 |
|
#xtan# |
6 |
|
#xtav# |
1500 |
|
#xtcm# |
500 |
|
#xtcv# |
183 |
|
#xd# |
383.0 |
|
#ts# |
13.8 |
| #itct# | 11:04 PM |
| #itctc# | 1 |
| #ftct# | 11:10 PM |
| #ftctc# | 2 |
| #mtct# | 11:33 PM |
| #xtct# | 11:20 PM |
| #mtav# | 314.7 |
| #mtan# | 2 |
| #xtav# | 344.7 |
| #xtan# | 4 |