Probe Redundancy PVT Defaults
-
Process variable 1 is probe 1
-
Process variable 2 is probe 2
-
Process variable 3 is temperature
-
Analog output 1 offset is 0
-
Analog output 1 range is 200
-
Analog output 1 offset is 0
-
Analog output 1 range is 200
-
First process control low limit is –100
-
First process control high limit is 100
-
First process control mode is such that setpoint of 0 shuts down and it is in dual mode
-
Second process control low limit is 0
-
Second process control high limit is 100
-
Second process control mode is such that it is in single reverse
-
Analog input 1 full scale is 2500
-
Analog input 2 full scale is 2500
-
Analog input 1 type is 2.5 volts
-
Analog input 2 type is 2.5 volts
-
Analog input 3 type is K thermocouple
-
20 minutes delay time before alarm
-
Band +/1 for alarm in millivolts is 10
-
Modbus at 9600 baud