Main Screen
The main screen is what appears when CAT-100 View is first opened. In order to utilize most of this screen, data must first be downloaded from a CAT-100 unit. This is performed with the Manage CAT100s option.
Figure 44 shows the layout of the CAT-100 View main screen. Lettered labels correspond to descriptions in Table 3 - Main Screen options and Table 4 - Main Screen display fields.
Figure 44 - CAT-100 View main screen
Main Screen Options |
||
Label in Fig 44 |
Name |
Description |
A |
Saved CAT100s drop-down list |
Opens a list of CAT-100 units that have been accessed by the program previously. When a CAT-100 unit is selected, data that has been downloaded for that unit is displayed. |
B |
Test Info button |
Opens a window containing information on a highlighted test |
C |
Edit Test button |
Allows for the modification of highlighted test data (NOTE: This does NOT change the data on the CAT-100 itself) |
D |
Delete Tests button |
Deletes highlighted test data |
E |
Show Live Coil button |
Displays coil data from a connected CAT-100 |
NOTE: If no CAT-100 data is loaded, the buttons (B, C, D, & E) will be grayed out.
|
Table 3 - Main Screen options
Main Screen Display Fields |
||
---|---|---|
Label in Fig 44 |
Name |
Description |
F |
Test Number |
The saved test number |
G |
Test ID |
The test ID (user-provided) |
H |
Time |
The time of the test recorded by the CAT-100 |
I |
Furnace |
The saved furnace number (user-provided) |
J |
Operator |
The saved operator identifier (user-provided) |
K |
Coil %C |
The recorded carbon potential of the coil used in the selected test |
L |
SP %C |
The carbon value of the process that is entered in the CAT-100 unit during the soak of the coil (user-provided) |
M |
SP °F |
The temperature setpoint (may be displayed in °C or °F; user-provided) |
N |
Avg Coil %C |
The average carbon potential for a particular Test ID |
O |
Deviation |
The difference between the Coil %C and the SP %C |
P |
Notes |
Test notes (added in CAT-100 View) |
Q |
Probe mV |
The probe millivolts (user-provided) |
R |
COF |
The CO factor (user-provided) |
S |
Probe Temp °F |
The probe temperature (may be displayed in °C or °F; user-provided) |
T |
Coil Factor |
The Coil Factor used in Carbon Potential calculation (entered by user during testing procedure) |
Table 4 - Main Screen display fields
With the exception of the Test Number, all of the fields can be changed by the user. When a field is changed, it is changed in CAT-100 View, but not on the CAT-100 itself.