Aux Input Module Offset Correction
This menu option will allow the user to enter offsets for the auxiliary inputs and apply any correction curves as needed. Adding an offset using this option will apply the offset to the entire curve, shifting each point by the same amount. First, A/I Offsets must be enabled by changing the value of the first row to Yes. Then, clicking on the value next to the appropriate input will display the option to enter an offset for that input. The offset can be in degrees + or -, and it is typically used to compensate for incorrect T/C wires.
Enable Offsets for SSi AIB
This will enable the use of offsets for any analog input boards. The options are: Yes or No.
Input 1 – Input 40
This is where the actual offsets will be entered for each input. The range is -50.0 – 50.0.
Input 0 Correction – Input 39 Correction