Relay Assignments
The 9210 Nitrider has the option of using eight relay outputs. All of the relays have a positive common terminal and independent negative terminals. All of the relays are configured in a normally closed position except relay number eight, which has both a normally closed (NC) and a normally open (NO) terminal. These relays can be configured to work with events, alarms, loops, and alarm combinations.
Relay Output Terminals
Relay Output 1 – terminals 7 and 8
Relay Output 2 – terminals 7 and 9
Relay Output 3 – terminals 7 and 10
Relay Output 4 – terminals 7 and 11
Relay Output 5 – terminals 7 and 12
Relay Output 6 – terminals 7 and 13
Relay Output 7 – terminals 7 and 14
Relay Output 8 – terminals 7 and 15 NC
Relay Output 8 – terminals 7 and 16 NO
Relay Output Choices
Loop1 fwd Event 3 burnoff
Loop1 rev Event 4 IN1 relay SP A
Loop2 fwd Event 5 IN1 relay SP B
Loop2 rev Event 6 IN1 relay SP C
Loop3 fwd Event 7 IN2 relay SP A
Loop3 rev Event 8 IN2 relay SP B
Programmer alarm Event 9 IN2 relay SP C
Alarm 1 Event 10 IN3 relay SP A
Alarm 2 Event 11 IN3 relay SP B
Alarm 3 Event 12 IN3 relay SPC
Event 0 Event 13 alarm combination
Event 1 Event 14 N/A
Event 2 Event 15
The “Alarm Combination” option will allow the user to select the specific combination of alarms to use.
Default Configuration
Relay Output 1 |
Event 0 |
Relay Output 2 |
Event 1 |
Relay Output 3 |
Event 2 |
Relay Output 4 |
Event 3 |
Relay Output 5 |
Event 4 |
Relay Output 6 |
Event 5 |
Relay Output 7 |
Loop 1 Reverse |
Relay Output 8 |
Programmer Alarm |