Valve Setup


This option will allow the user to set up the valves for the 9210 Nitrider.  There is a choice of four valves.

 

Zero Scale

The Zero Scale option will allow the user to set the zero scale for the valve.  This value must be less than or equal to the Valve Max value.

 

Full Scale

This option will allow the user to set the full scale for the vale.  This value must be less than or equal to the Valve Max value.

 

Trim Enable

This option will allow the user to set the trim enable option for the valve.  The options are Yes or No.

 

Target Setpoint

The Target Setpoint option will allow the user to set the target setpoint for the valve.  This value must be less than or equal to the Valve Max value.

 

Trim Range

This option will allow the user to set the trim range for the valve.  This value must be less than or equal to the Valve Max value.

 

Zero SP Scale

This option will allow the user to set the zero scale for the setpoint.  This value must be less than or equal to the Valve Max value.

 

Full SP Scale

This option will allow the user to set the full scale for the setpoint.  This value must be less than or equal to the Valve Max value.

 

Valve Max

This option will allow the user to set the maximum flow rate for the valve.  The range is 0 to 32767.

 

Deviation Setpoint

This option will allow the user to set the deviation setpoint for the valve. The range is 0 (OFF) to 32000.

 

Deviation Alarm Delay (Seconds)

This option will allow the user to set the deviation alarm delay, listed in 1/10th of minutes.  The range is 0 to 32000Note: The alarm delay is entered in 1/10th of a minute intervals, but it is displayed in seconds, so 3/10 of a minute = 18 seconds.

 

Gas Type

This option will determine the gas type for the valve.

 

Valve Decimal Place

This option will set the decimal place for the valve.  The range is 0 through 4.

 

Standard Setup for Flow Alarms with Delays

The “Deviation Setpoint” is the flow alarm setpoint, and the “Dev. Alarm Delay (sec)” is the flow alarm delay time

 

Valve 1

Valve 2

Valve 3

Valve 4

Zero Scale

0

0

0

0

Full Scale

300

300

150

0

Trim Enable

No

Yes

No

no

Target Setpoint

150

150

10

0

Trim Range

0

50

25

0

Zero SP Scale

0

0

0

0

Full SP Scale

300

300

150

0

Valve Max

300

300

150

0

Deviation Setpoint

20

60

10

Off

Dev. Alarm Delay (sec)

300

60

300

0

Gas Type

Nitrogen

Ammonia

Dissociated Ammonia

Hydrogen

Valve Decimal Place

0

0

0

0