Controller Description

The Model 9210-Nitriding instrument is a multi-loop Proportional Integral Derivative (PID) controller that can be custom configured to control up to three Nitriding process loops. General features of this product include:
The Model 9210 is powered by 24 VDC, NOT LINE Voltage. Please be careful when connecting power to this controller. Connecting anything other then 24 VDC will cause serious damage.
|
Approximate Box Dimensions |
2.75" x 4" x 4.5" |
|
Power Requirements |
24VDC, 4 Watts |
|
Temperature Range |
32˚F - 132˚F |
|
Digital Output Rating |
300VAC / 1 AMP |
|
Analog Output Load Rating |
1000 Ohms (Total) |
|
Controller Enclosure Rating |
IP10 – hand protected |
|
Number of RS232 Ports |
Two (2) |
|
Number of Ethernet Ports |
One (1) |
|
Number of RS485 Host Ports |
One (1) |
|
Number of RS485 client Ports |
Two (2) |
|
Number of Internal Relays |
Eight (8) |
|
Number of Analog Inputs |
Three (3) |
|
Number of Analog Outputs |
Two (2) |
|
Number of Digital Inputs |
Four (4) |
|
Number of Control Loops |
Three (3) |
The control enclosure is powered by 120 VAC, Single Phase, 60 Hz (Line Power). Line voltage for the isolation relays comes from the same source.