client Instrument Setup
** All devices on the same client port must utilize the same protocol
** An address of zero (0) will disable the instrument** Some controllers (AC20 for example) can provide dual functions (atmosphere and events) and must have the same address assigned for both.
Clicking on the “Value” field for any instrument will allow the user to select the client instrument.
Instrument
This value will allow the user to select the client instrument type.
Atmosphere Controllers
Some Atmosphere controllers will have an [A] in front of the name
SSI AC20 Eurotherm 2404 MGA
Yokagowa 750 Eurotherm 2500
Honeywell UDC 3300 Carbpro v3.5
Dualpro LP1 modbus Carbpro v3.0
Dualpro LP2 modbus Carb PC
Dualpro LP1 MMI 9200 LP1
Dualpro LP2 MMI IR Base
Temperature Controllers
Some Temperature controllers will have a [T] in front of the name
SSi 7EK 9200 LP1 SSi Quad AO1
Yokagowa 750 9200 LP2 SSi Quad AO2
Honeywell UDC 3300 9200 LP3 SSi Quad AO3
Dualpro LP1 modbus 9100 LP2 SSi Quad AO4
Dualpro LP2 modbus Eurotherm 2704 LP1 Yokogawa UT350
Dualpro LP1 MMI Eurotherm 2704 LP2 Yokogawa 750 LP 2
Dualpro LP2 MMI Eurotherm 2704 LP3 Yokogawa UP350
Eurotherm 2404 VC base 1 Honeywell DCP551
Eurotherm 2500 VC base 2 Ascon 08
Unipro v 3.5 VC base 3 SSi X5
Unipro v 3.0 VC base 4 SSi M4L
Carbpro v3.5 client AIPC SSi X5/Timer
Carbpro v3.0 client SSI 7SL
10pro AEC Flow Board
Dualpro in C UMC800 LP1
Event controllers
SSI AC E Micrologix PLC User 7
Yokagowa 750E MCM Module User 8
Mod Mux PLC5 DF1 User 9
Dualpro E Modbus SLC DF1 User 10
Dualpro E MMI User 1 User 11
Carbpro E v3.5 User 2 User 12
Carbpro E v3.0 User 3 User 13
Eurotherm 2500 User 4 User 14
Ssi 8-8 User 5 User 15
SSi 9200 E User 6 User 16
Address
This value allows the user to select the address that corresponds with the controller selected, with a range of 0 to 249.
Port
The options for this field can either be client 1, client 2, or RS-232.
client 1 – terminals 5(-), 6(+)
client 2 – terminals 22(+), 23(-)