AUX SP Configuration
This menu is used to setup and assign a setpoint to be transmitted to a client instrument. The Offset and Delay Time parameters are used to modify the setpoint and when it is sent to the client instrument. This feature is limited to client Instruments 1, 2, and 3. This menu option is typically used to retransmit an alarm setpoint value to an overtemp controller.
The “Retrans to client 1”, “Retrans to client 2”, and “Retrans to client 3” menu options each have four options to select: Off, Loop 1, Loop 2, or Loop 3. These options will allow the user to select which, if any, values to retransmit to the selected client instrument.
The “Setpoint Offset Sl 1”, “Setpoint Offset Sl 2”, and “Setpoint Offset Sl 3” menu options can be a number between –32768 and 32767. These options will allow the user to set the destination offset for the selected client instrument.
The “Setpoint Delay Sl 1”, “Setpoint Delay Sl 2”, and “Setpoint Delay Sl 3” menu options can be a number between –32768 and 32767. These options will allow the user to set the delay, in seconds, before the setpoint is retransmitted to the selected client instrument.