Appendix D – 9205 Instrument Alarms

 

This appendix provides a list of alarms programmed into the 9205 controller. The table below provides the alarm name, alarm text (as presented in Configurator), the condition(s) under which the alarm is generated, and information on user-accessible settings that affect the triggering of the alarm.

 

Alarm Description

Register/Bit Location

Type

Values

Alarm Condition(s)

Applicable User-Configurable Setting(s)

Programmer (any) alarm

141/0

Programmer

 

 

 

Alarm 1

141/1

Main

 

 

 

Alarm 2

141/2

Main

 

 

 

Alarm 3

141/3

Main

 

 

 

TC redundancy alarm

141/7

 

 

 

 

Internal System Error

141/8

 

 

Analog input CPU is no longer responding to the 9205's main CPU.

 

TC Check 1->2 out of band

141/9

 

 

 

 

TC Check 1->3 out of band

141/10

 

 

 

 

TC Check 2->3 out of band

141/11

 

 

 

 

End of Quench

141/12

 

 

 

 

Programmer 2 (any) alarm

141/14

 

 

 

 

Client coms (any) alarm

141/15

 

 

 

 

TC rise too great

163/0

Burnoff

 

 

 

mV insufficient drop

163/1

Burnoff

 

 

 

slow recovery

163/2

Burnoff

 

 

 

impedance too high

163/3

Burnoff

 

 

 

PLC Alarms (custom)

2980 - 2989

PLC

 

 

 

user alarm

25024/0

Programmer

 

 

 

deviation, atmosphere

25024/1

Programmer

 

 

 

high atmosphere

25024/2

Programmer

 

 

 

low atmosphere

25024/3

Programmer

 

 

 

deviation, temperature

25024/4

Programmer

 

 

 

high temperature

25024/5

Programmer

 

 

 

low temperature

25024/6

Programmer

 

 

 

high atm % output

25024/7

Programmer

 

 

 

low atm % output

25024/8

Programmer

 

 

 

high temperature % output

25024/9

Programmer

 

 

 

low temperature % output

25024/10

Programmer

 

 

 

gosub

25024/11

Programmer

 

 

 

limit

25024/12

Programmer

 

 

 

internal system error

25024/13

Programmer

 

 

 

hold alarm

25024/14

Programmer

 

 

 

Client coms alarm (any)

25024/15

Programmer

 

 

 

 

 

 

 

 

 

User alarm

25028

Programmer

0 - 99

 

 

deviation, atmosphere

 

 

101

 

 

high atmosphere

 

 

102

 

 

low atmosphere

 

 

103

 

 

deviation, temperature

 

 

104

 

 

high temperature

 

 

105

 

 

low temperature

 

 

106

 

 

high atmosphere % output

 

 

107

 

 

low atmosphere % output

 

 

108

 

 

high temperature % output

 

 

109

 

 

low temperature % output

 

 

110

 

 

gosub

 

 

111

 

 

limit

 

 

112

 

 

checksum error

 

 

113

 

 

load TCs out of band

 

 

114

 

 

hold alarm (step programmer)

 

 

115

 

 

internal system error

 

 

116

 

 

hold alarm (segment programmer)

 

 

117

 

 

hold alarm (guarantee)

 

 

118

 

 

bad PID values loaded

 

 

125

 

 

quench transfer time exceeded

 

 

140

 

 

Client instrument coms (1-based instrument number + 200).

 

 

201 + inst #

 

 

Currently not supported

 

 

401