Client Instrument Setup

Slave Instrument Setup Menu

** All devices on the same Client port must utilize the same protocol

** An address of zero (0) will disable the instrument** Some controllers (AC20 for example) can provide dual functions (atmosphere and events) and must have the same address assigned for both.

 

Clicking on the “Value” field for any instrument will allow the user to select the Client instrument.

 

Instrument


This value will allow the user to select the Client instrument type.

 

 

 

 

 

 

 

 

List of Instruments

The following is the list of instruments available as Client instruments:

SSi AC20            [T]Eurotherm 2500        SSi Quad AO2        Carbpro E v3.0

[A]Yokogawa 750        Unipro v3.5            SSi Quad AO3        Eurotherm 2500

[A]Honeywell UDC3300        Unipro v3.0            SSi Quad AO4        Ssi 8-8

[A]Dualpro LP1 Modbus        [T]Carbpro v3.5 Client        Yokogawa UT350    SSi 9200 E

[A]Dualpro LP2 Modbus        [T]Carbpro v3.0 Client        Yokogawa 750 Lp 2    Micrologix PLC

[A]Dualpro LP1 MMI        10Pro                Yokogawa UP350    MCM Module

[A]Dualpro LP2 MMI        Dualpro IN C            Honeywell DCP551    PLC DF1

[A]Eurotherm 2404        [T]9200 LP1            Ascon 08        SLC DF1

[A]Eurotherm 2500        [T]9200 LP2            SSi X5            User 1

[A]CarbPro v3.5            [T]9200 LP3            SSi M4L            User 2

[A]CarbPro v3.0            9100 LP2            SSi X5/Timer        User 3

CarbPC                Eurotherm 2704 LP1        SSi SPUD        User 4

[A]9200 LP1            Eurotherm 2704 LP2        SSi AIB3        User 5

IR Base                Eurotherm 2704 LP3        SSi H2 Cell        User 6

MGA                VC Base 1            Flow Meter Short    User 7

SSi 7EK                VC Base 2            SSi O2 Remote        User 8

[T]Yokogawa 750        VC Base 3            SSi Dual Motor Board     User 9

[T]Honeywell UDC3300        VC Base 4            SSi AC E        User 10

[T]Dualpro LP1 Modbus        AIPC                Yokogawa 750E        User 11

[T]Dualpro LP2 Modbus        SSi 7SL                Mod Mux        User 12

[T]Dualpro LP1 MMI        SSi eFlo            Dualpro E Modbus    User 13

[T]Dualpro LP2 MMI        UMC800 LP1            Dualpro E MMI        User 14

[T]Eurotherm 2404        SSi Quad AO1            Carbpro E v3.5        User 15

                                            User 16

 

Address

This value allows the user to select the address that corresponds with the controller selected, with a range of 0 to 249.

 

Port

The options for this field are: Client 1, Client 2, RS-232, IP Address 1, IP Address 2, IP Address 3, IP Address 4, Passive, or Client 3/RS-232.

Client 1 – terminals 5(-), 6(+)

Client 2 – terminals 22(+), 23(-)

RS-232