Burnoff Setup
This menu option allows the user to modify the settings that are associated with the probe burnoff (menu option Burnoff).
Burnoff Time
The amount of time from the beginning of the burnoff to the end of the burnoff measured in seconds. Clicking on the value will allow the user to change the value.
Burnoff Recovery Wait Time
The amount of time allotted to allow the probe measurements to return to a stable, accurate range after the burnoff is complete. This is measured in seconds. The control output is held until this time is elapsed. Clicking on the value will allow the user to change the value.
Burnoff Interval
The amount of time between the beginning of one burnoff and the beginning of the next scheduled burnoff measured in minutes. Clicking on the value will allow the user to change the value.
Burnoff Minimum Millivolts
The minimum measured millivolt tolerance of the probe required to start a burnoff. Clicking on the value will allow the user to change the value.
Burnoff Maximum Temperature
The maximum measured temperature allowed during a burnoff. If the temperature value is exceeded the burnoff will stop. This is done to help maintain the life and the accuracy of your probe. Clicking on the value will allow the user to change the value.