DESCRIPTION

 

The 13011 probe conditioning system is designed for use with a batch furnace. Although many such furnaces are equipped with programmable controls that could conduct probe conditioning on a regular basis, it has been our experience that this programming capability is seldom used. Existing burnoff systems that are designed to work with a programmable controller cannot be used as "stand alone" systems without significant modification. Further, most cannot provide adequate air for burnoff because they simply switch the output of low flow reference air pumps to the burnoff fitting without regard to adequate flow. The 13011 is further designed to use combustion air for both reference and burnoff functions. Fig. 1 shows the piping and wiring diagram of the 13011.